Acoustic Panels: Which Type to Choose for a Restaurant or Hotel Room — Materials, NRC and What Really Absorbs Sound
Acoustic panels compared: PET felt, mineral wool, wood slat, melamine foam. NRC values, thickness and fire class, with a table for restaurants, rooms and lobbies.

A good restaurant or lobby can be ruined by one mistake: a beautiful interior of glass, concrete and stone that sounds like a swimming pool. Guests shout across the table, waiters ask for orders twice, and the reviews start with “very noisy”. Acoustic panels are the most common fix, but the name covers very different products — from 9 mm PET felt to mineral wool boards that absorb many times more than a decorative slat.
This guide is for designers, restaurant and hotel owners, managers and developers choosing acoustic finishes. We cover how absorption differs from insulation, what NRC and reverberation time mean, the main panel types, where each really works and where it only looks good, and what to put in the contract if you order panels directly from a factory.
Absorption, insulation and reverberation: three different jobs
The biggest confusion in this topic is mixing up the concepts. A client says “I want to deaden the sound” and buys panels that solve the wrong problem.
- Sound absorption reduces echo inside a room. The sound wave enters a porous material, loses energy and does not bounce back. This is what acoustic panels, ceiling clouds, curtains and carpets do.
- Sound insulation keeps noise from reaching the next room. It relies on mass (double-layer drywall, concrete), airtight joints and an air gap. A decorative panel on a wall barely improves insulation.
- Reverberation time (RT60) is the time for sound to decay by 60 dB. A reasonable target is about 0.6–0.9 s for a restaurant and 0.6–0.8 s for a meeting room; lobbies can tolerate more. An empty room with glass and stone easily reaches 1.5–2.5 s — that is the “it’s loud in here” feeling.
So if the problem is hall echo, you need high-absorption panels. If you can hear neighbours through the wall, panels will not help; the partition construction must change (more on materials in our guide to insulation and soundproofing types).
What NRC means and how to read a catalogue
The headline figure is NRC (Noise Reduction Coefficient): the average absorption coefficient α at 250, 500, 1000 and 2000 Hz, rounded to 0.05. It is measured in a reverberation chamber under ISO 354 or ASTM C423. In Europe the single-number αw under ISO 11654 (classes A–E) is more common.
How to read the numbers:
- NRC 0.0–0.3 — mostly reflective (concrete, glass, drywall, tile).
- NRC 0.4–0.6 — moderate absorption: thin felt and fabric panels, unfilled perforated slats.
- NRC 0.7–0.9 — high absorption: 25–50 mm mineral or glass wool, 12–25 mm PET felt with an air gap, melamine foam.
- NRC 1.0 and above is possible for thick panels with an air gap; a value over 1 is not an error but a result of rounding and edge effects in testing.
Two warnings. First, NRC averages frequencies: a panel can handle speech (500–2000 Hz) well and barely touch bass (125 Hz) — for live music in a bar, look at the full octave-band table. Second, an NRC figure in a Chinese factory catalogue with no report number and no named laboratory is advertising; ask for a report on exactly this model and exactly this thickness.
Main types of acoustic panels
PET felt (polyester fibre)
A panel of recycled PET fibres hot-pressed together. Typical thickness is 9 or 12 mm for walls and 24 mm or more for ceilings and dividers. Weight is about 1500–2200 g/m² for 9 mm. Dozens of colours, plus laser cutting, engraving and 3D forming.
Pros: light, dust-free, tolerates humid air, easy to cut, FR versions have good fire performance. Cons: weaker than mineral wool at low frequencies, cheap versions look “school-like”, light colours collect dust near AC outlets.
Mineral or glass wool in a fabric or veneer facing
A glass or basalt wool board with a density of 40–100 kg/m³, wrapped in acoustic fabric or veneer. This is “professional” acoustics, giving the best absorption at 25–50 mm. Pros: NRC 0.8–1.0, fire resistance, low-frequency performance when mounted with a gap. Cons: needs a protective facing (loose fibre must not be exposed), heavier, costlier to install.
Wood slat panels on a felt backing
The popular designer option: MDF-veneer or solid slats on a PET felt backing. Gaps of 8–15 mm let sound reach the felt. Pros: warm look, good for restaurants, lobbies and reception. Cons: real absorption comes from the backing and the open-area percentage, not the wood; veneer and MDF have a lower fire class, and in humid areas you need moisture-resistant MDF or aluminium with a wood finish.
Perforated panels (MDF, plasterboard, metal)
A sheet with holes or slots with mineral wool or felt behind it. The effect depends on perforation percentage (typically 10–25%) and hole size. Pros: monolithic look without visible joints, high fire class (plasterboard, aluminium). Cons: perforation without fill does almost nothing; higher price.
Polyurethane and melamine foam
Polyurethane (PU) — “egg crate” panels and wedges, familiar from studios. Hotels rarely use them: weak fire class and a cheap look, even though 25–35 kg/m³ foam absorbs reasonably. Melamine foam is the exception: non-combustible (B-s1,d0), light and suitable for ceilings in public areas.
Fabric wall panels (“soft walls”)
A frame with 25–50 mm fill wrapped in fabric (polyester, wool, velvet). Good for rooms, ballrooms and spas: absorption plus a soft look, often doubling as a headboard. Cons: fabric picks up dirt and odours, so restaurants with an open kitchen need a washable or treated finish.
Ceiling clouds and baffles
Suspended elements that absorb from both sides and cover less area than a full ceiling. In restaurants with high ceilings this is the most effective way to cut reverberation without touching the walls.
Comparison table: type, NRC, where to use
| Panel type | Thickness | Typical NRC | Fire class | Where to use | Weak point |
|---|---|---|---|---|---|
| PET felt 9–12 mm | 9–12 mm | 0.45–0.65 | B-s1,d0 (FR version) | Rooms, lobbies, co-working | Low frequencies |
| PET felt 24 mm+ | 24–30 mm | 0.7–0.9 | B-s1,d0 | Restaurants, ceiling clouds | Higher price |
| Glass / mineral wool with facing | 25–50 mm | 0.8–1.0 | A1–A2 | Ballrooms, cinemas, banquet halls | Needs facing, weight |
| Wood slats on felt | 20–30 mm | 0.5–0.85 (depends on backing) | B–C for MDF | Lobbies, reception, restaurants | Moisture, veneer fire class |
| Perforated plasterboard / MDF | 12.5–25 mm + fill | 0.5–0.8 | A2–B | Meeting rooms, ceilings | Useless without fill |
| Melamine foam | 25–50 mm | 0.8–0.95 | B-s1,d0 | Public-area ceilings | Fragile surface |
| Polyurethane (“egg crate”) | 30–50 mm | 0.6–0.9 | Often below B | Studios, technical rooms | Fire safety |
| Fabric wall panels | 25–50 mm | 0.6–0.9 | B–C | Rooms, spas, headboards | Dirt, odours |
Values are indicative for typical products; for a specific model, read the ISO 354 / ASTM C423 report.
What to choose for each task
Restaurant and bar. The enemies are reflective surfaces and a high ceiling. A combination works: ceiling clouds or baffles in 24 mm+ PET felt, or perforated ceiling panels with mineral wool, plus slat panels on the walls where guests sit. Think in terms of equivalent absorption area: a rough guide is to cover about 30–50% of the ceiling area with absorptive material, or the equivalent on walls. The exact calculation is the acoustician’s job based on RT60.
Hotel room. The task is different: isolation from the corridor and neighbours, and a comfortable background. Panels over the headboard, a soft wall behind the bed, heavy curtains, carpet — and a good door. 9–12 mm PET felt or fabric panels solve in-room echo; sound through the wall is stopped by partition construction.
Lobby and reception. Design matters more here: wood slats on felt, perforated panels matched to the interior. Do not forget fire class and mounting height.
Meeting and banquet halls. Speech without echo: 40–50 mm mineral wool in a facing on walls and a perforated ceiling. Dividing walls between halls are a separate insulation question.
Spa, pool, semi-open areas. Humidity and chlorine. Aluminium perforated panels with powder coating, hydrophobic PET and moisture-resistant mineral ceilings work. Unprotected wood veneer does not survive.
Fire safety and emissions
Acoustic finishing is a large area of potentially combustible material in a public space, so it is checked harder than most things. What to look at:
- Fire class: EN 13501-1 (B-s1,d0 or better for most public areas) or ASTM E84 Class A. The report must cover the specific material, not a product “family”.
- Smoke and droplets: the s1/d0 indices matter more than they seem — smoke is more dangerous than flame.
- Formaldehyde emission: for MDF and veneered panels, class E1 or better (E0, CARB P2).
- Odour: synthetics and adhesives on new panels can smell for weeks; for rooms, request a sample and smell-test it.
From Dream View practice: factory checklist for acoustic panels
We do not publish the prices of specific projects, but this is what our team uses to inspect a batch of acoustic panels before shipping:
- Match to the report. Thickness and density on the sample match the NRC report. If the report was run on a 24 mm panel and the batch is 12 mm, the report does not apply to your order.
- Weighing. Pull a 1 m² panel from the sample and weigh it: for PET felt, weight per unit area is the simplest indicator of how much fibre is really inside.
- Bonding and edges. For slat panels the backing must be glued along the full length with no lifting and the slats on an even pitch.
- Colour across the batch. Check veneer and fabric against the approved sample in daylight and warm light; fix the tolerance in the contract.
- Odour and formaldehyde. Seal a sample in a bag for a few hours and smell it; request the E1 report.
- Packing. Edges in corner protectors, no panels lying flat under heavy loads — PET felt that deforms during 40 days in a container does not recover.
A typical mistake from sourcing: the client approves a sample slat on a nice backing, and in the production batch the factory saves on felt — thinner or lighter. It is hard to tell by eye, acoustic performance drops, and this is only found after installation. The protection is weight and thickness in the contract specification and a sample inspection under AQL before shipping (see AQL in plain words).
Installation: what to watch
- Air gap. A panel fixed on battens 50–100 mm from the wall absorbs low frequencies noticeably better than one glued flat.
- Fixing method. Glue, Z-profile, rails, hangers: for a ceiling in a public area use mechanical fixing, not glue.
- Services. Lights, sensors and sprinklers must be coordinated before installation.
- Coverage. Distribute panels evenly rather than putting everything on one wall.
Prices and ballparks
Prices depend heavily on thickness, density and finish. By order of magnitude: 9–12 mm PET felt is clearly cheaper than slat panels on a backing, while mineral wool panels in a fabric or veneer facing and designer veneer slats sit at the top. The main price drivers are material thickness, fire class, finish (veneer, laser cutting, custom colour) and batch size.
In direct factory purchasing these items are usually well below European catalogue prices: for finishing materials we aim for savings from 20%, and we calculate the exact figure against a specific specification rather than “from a catalogue”. It makes sense to spend part of the savings on what cannot be fixed after installation — RT60 measurement and batch inspection.
One more practical tip: order 3–5% extra area. Cutting around lights and corners and damage during installation eat material, and matching a panel from a different batch is nearly impossible.
How to buy panels directly in China
China is the main producer of PET felt and slat panels, and also makes mineral wool boards and perforated sheets. But factories differ in density, adhesive composition and the honesty of their reports. To avoid buying “acoustics” without acoustics:
- Request a technical specification: thickness, density (g/m² or kg/m³), composition, fire class, formaldehyde.
- Get samples and confirmation of the NRC / αw report for the same model.
- Fix tolerances for size, colour and thickness, Incoterms 2020 terms and staged payment.
- Run an AQL inspection before loading and check the packing.
- Determine the HS code and duties in advance so the estimate does not move at customs.
For how we organise finishing material purchases, see our guide to sourcing building materials from China. If you need an agent to check the factory, samples and batch, see the China sourcing agent service.
Summary
Acoustic panels are not about “a nice wall covering” but about a calculation: how much absorption, over what area and at which frequencies. For restaurants and banquet halls choose thick panels with high NRC and add ceiling clouds; for rooms use soft walls and felt at the headboard plus a proper partition; for wet areas use aluminium and hydrophobic PET. And demand documents: the NRC report, fire class and formaldehyde class.
Dream View works directly with Chinese factories: we select suitable panels, check samples and batches, fix our fee in the contract before work starts and deliver by sea in 30–45 days after production. Send drawings or a list of rooms and we will prepare a free estimate: orders@dreamviewchina.com, +66 80 942 2230, t.me/dreamviewchina.
Frequently asked questions
What is NRC and what value do I need for a restaurant?
NRC (Noise Reduction Coefficient) is the average sound absorption coefficient at 250, 500, 1000 and 2000 Hz, rounded to the nearest 0.05. A value of 0 means total reflection; 1.0 means almost total absorption. For restaurants and lobbies aim for NRC 0.7 or higher over a meaningful area; for a hotel room NRC 0.4–0.6 on selected walls is usually enough. Always ask for the test report, not the word "acoustic" in a catalogue.
What is the difference between sound absorption and sound insulation?
Absorption reduces echo and reverberation inside a room: soft, porous materials soak up reflected sound. Insulation stops sound passing through a wall or floor, and needs mass, airtightness and an air gap. Decorative acoustic panels solve the first problem; to stop noise from the next room you need a partition with mineral wool and double boarding.
Which acoustic panels absorb the most sound?
Glass wool and mineral wool, PET felt and melamine foam from about 25–40 mm thick give the best mid and high-frequency absorption. Wood slat and perforated panels only perform well if the perforation is right and there is absorbent fill behind them. The thicker the panel and the bigger the air gap behind it, the better it handles low frequencies.
What fire rating do acoustic panels need in a hotel?
Requirements depend on the country of the project. In practice buyers ask for B-s1,d0 or better under EN 13501-1, or ASTM E84 Class A, and A2 or better on escape routes. Untreated polyurethane foam and thin synthetic materials often fail. Ask the factory for the fire test report before ordering and have your designer check it against local code.
Can acoustic panels be used in humid climates or on terraces?
Indoors with air conditioning, yes: PET felt and mineral wool in a protective facing tolerate ambient humidity. For semi-open areas choose PET with a hydrophobic treatment or aluminium; wood slats and MDF veneer swell and delaminate. Put moisture resistance and adhesive type in the contract — in the tropics the glue is usually what fails first.
Can I order acoustic panels from China?
Yes. China is the largest producer of PET felt, wood slat panels, perforated MDF and mineral wool boards. The range is huge and so is the spread in quality, so check density, thickness, the NRC report and formaldehyde class. You need samples, a contract with technical parameters and an AQL inspection before loading.
Sources
- WCO — What is the Harmonized System (HS)?(wcoomd.org)
- ICC — Incoterms 2020 rules(iccwbo.org)